linux – 是UNC S.M.A.R.T.错误严重吗?需要采取行动?
发布时间:2020-05-23 22:56:48 所属栏目:Linux 来源:互联网
导读:我有一台300G Western Digital Raptor,最近展示了UNC SMART,想知道有经验的人是否应该更换它并获得WD的保修? smartctl -a的详细信息如下: smartctl 5.41 2011-06-09 r3365 [FreeBSD 8.2-RELEASE-p6 amd64] (local build)Copyright (C) 2002-11 by Bruce A
|
我有一台300G Western Digital Raptor,最近展示了UNC SMART,想知道有经验的人是否应该更换它并获得WD的保修? smartctl -a的详细信息如下: smartctl 5.41 2011-06-09 r3365 [FreeBSD 8.2-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-11 by Bruce Allen,http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Western Digital VelociRaptor
Device Model: WDC WD3000HLFS-01G6U0
Serial Number: WD-WXD0C79C8807
LU WWN Device Id: 5 0014ee 0ac3cfaf0
Firmware Version: 04.04V01
User Capacity: 300,069,052,416 bytes [300 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Thu Apr 19 16:03:33 2012 CST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x84) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 4800) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 59) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x303f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 195 195 051 Pre-fail Always - 49036
3 Spin_Up_Time 0x0003 199 196 021 Pre-fail Always - 3008
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 425
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x000e 200 200 000 Old_age Always - 0
9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 10292
10 Spin_Retry_Count 0x0012 100 100 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 404
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 268
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 426
194 Temperature_Celsius 0x0022 117 100 000 Old_age Always - 30
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 200 200 000 Old_age Offline - 4
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 1
SMART Error Log Version: 1
ATA Error Count: 749 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on,and printed as
DDd+hh:mm:SS.sss where DD=days,hh=hours,mm=minutes,SS=sec,and sss=millisec. It "wraps" after 49.710 days.
Error 749 occurred at disk power-on lifetime: 6972 hours (290 days + 12 hours)
When the command that caused the error occurred,the device was active or idle.
After command completion occurred,registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 44 cb 53 40 Error: UNC at LBA = 0x0053cb44 = 5491524
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 40 10 a6 4e 58 01 08 00:16:23.812 READ FPDMA QUEUED
60 08 10 9e 32 5b 00 08 00:16:17.646 READ FPDMA QUEUED
60 08 10 9e 32 5b 00 08 00:16:17.645 READ FPDMA QUEUED
ef 02 00 00 00 00 00 08 00:16:17.645 SET FEATURES [Enable write cache]
60 08 10 9e 32 5b 00 08 00:16:11.412 READ FPDMA QUEUED
Error 748 occurred at disk power-on lifetime: 6972 hours (290 days + 12 hours)
When the command that caused the error occurred,registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 44 cb 53 40 Error: UNC at LBA = 0x0053cb44 = 5491524
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 08 10 9e 32 5b 00 08 00:16:11.412 READ FPDMA QUEUED
60 08 10 9e 32 5b 00 08 00:16:11.412 READ FPDMA QUEUED
ef 02 00 00 00 00 00 08 00:16:11.412 SET FEATURES [Enable write cache]
60 00 30 1e cb 53 06 08 00:16:05.199 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:16:05.180 READ FPDMA QUEUED
Error 747 occurred at disk power-on lifetime: 6972 hours (290 days + 12 hours)
When the command that caused the error occurred,registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 44 cb 53 40 Error: UNC at LBA = 0x0053cb44 = 5491524
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 30 1e cb 53 06 08 00:16:05.199 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:16:05.180 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:16:05.178 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:16:05.178 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:16:05.178 READ FPDMA QUEUED
Error 746 occurred at disk power-on lifetime: 6972 hours (290 days + 12 hours)
When the command that caused the error occurred,registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 44 cb 53 40 Error: UNC at LBA = 0x0053cb44 = 5491524
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 30 1e cb 53 06 08 00:15:58.945 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:58.945 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:58.945 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:58.945 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:58.944 READ FPDMA QUEUED
Error 745 occurred at disk power-on lifetime: 6972 hours (290 days + 12 hours)
When the command that caused the error occurred,registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 44 cb 53 40 Error: UNC at LBA = 0x0053cb44 = 5491524
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
60 00 30 1e cb 53 06 08 00:15:52.727 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:52.727 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:52.727 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:52.727 READ FPDMA QUEUED
60 00 30 1e cb 53 06 08 00:15:52.726 READ FPDMA QUEUED
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests,use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans,do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up,resume after 0 minute delay.
解决方法如果可以,请进行更换.另一方面,这些是“唯一的”读取错误并没有那么糟糕.如果你写信给那个部门,那么你只能确定它是否有缺陷. 如果有问题,我会运行供应商实用程序来检查(它们也运行智能测试).他们通常会提供可启动的CD. 你可以而且应该运行一个自测试,你可以通过发布来从linux做 smartctl -t long /dev/your-device 等几个小时(它会显示估计).然后再次检查 smartctl -a /dev/your-device 如果它说完成没有错误你没事.如果没有去供应商实用程序检查驱动器. (编辑:安卓应用网) 【声明】本站内容均来自网络,其相关言论仅代表作者个人观点,不代表本站立场。若无意侵犯到您的权利,请及时与联系站长删除相关内容! |
相关内容
- linux – UDP Packet drop – INErrors Vs .RcvbufErrors
- ruby – 什么是一个很好的开源软件包,用于在大型Rails站点上
- 在Linux中传递PHP和C可执行文件之间的数据
- LINUX教学:sudo 出现unable to resolve host 解决方法
- linux – 在/etc/init.d脚本中调用守护进程是阻塞的,而不是
- linux – 在/ var / www中处理Apache 2用户www-data权限的最
- 如何阅读Linux’w’命令输出中的“IDLE”列?
- linux – 从命令行下载图像
- 从一个专用的Linux服务器迁移到另一个?
- linux – 本地SVN存储库到git